Jun 26, 2024|

The installation of acid dew point sensor is quite simple. First, drill a hole at the predetermined installation position, weld a 1.5-inch BSP or NPT nut, and then screw the acid dew point sensor in. If a flange was used previously, just machine a 1.5-inch BSP or NPT screw hole in the center of the corresponding flange, screw the H2SO4 acid dew point transmitter

Boiler flue gas H2SO4 acid dew point transmitter sensor for boiler flue gas

To extend the service life of the acid dew point sensor and prevent smoke clogging, the sensor should usually be installed vertically. If horizontal installation is required, it is recommended to maintain an angle of 15 to 30 degrees. When the furnace stops burning, the water vapor in the flue and the flue gas in the furnace condenses and flows out of the H2SO4 acid dew point transmitter

H2SO4 acid dew point transmitter to the boiler flue gas online acid dew point meter. The thermocouple connection wire in the cable is a K-type or R-type thermocouple compensation wire. The thermocouple connection of the dedicated cable uses the corresponding compensation wire, and the electrode and thermocouple signal wire are shielded to prevent interference signals from affecting the measurement accuracy.

 

Gửi yêu cầu